2Display of 1/3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. On one screen, convenient for contrastively diagnosing. 3Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements. 4With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor's burden.
5Build-in memory, which is convenient for doctor to review case and statistic. 6Multi- language(Chinese, English) interface and report. 7Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, import real-time data to the software for analyzing and report printing, and old cases stored in Electrocardiograph can be uploaded to PC.
8Power supply: AC/DC and built-in rechargeable lithium battery, which meets the requirements of visiting a patient at home and body examination. Input way: Floating and defibrillation protection. Frequency response:0.01150 Hz(-3 dB). Filter: power frequency(AC50/60 Hz), myoelectricity25 Hz/35 Hz (-3 dB), baseline drift filter. Recording way: Thermal printing system. Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper. Time base selection(paper speed):6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%. Gain control(sensitivity): 2.5, 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV. Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze.Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5) amplitude, S(V1) amplitude, R(V5)+S(V1) amplitude.
Product safety type: Class I type CF defibrillation-proof applied part. ECG signal input sampling frequency: 32 kHz. Waveform data processing sampling frequency: 1 kHz. The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected. Accuracy of input signal: ±5 %.Calibration voltage:1 mV±2 %. Input circuit current:=0.01 uA.
50Hz interference suppression filter:=20 dB. Pacing detection channel: all leads.
DC: 7.4V/5000mAh rechargeable lithium battery. Degree of protection against ingress of liquid: IPX0. Atmospheric pressure: 700 hPa1060 hPa. Atmospheric pressure: 500 hPa1060 hPa.Dimension: 315mm(L)×200mm(W)×77mm(H). Food and Drug Administration and state and local regulatory agencies. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE, TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved.
Whatsapp:+86 18716007715; Skype:contec. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\ECG & EKG Machines". The seller is "contecmedical826" and is located in this country: CN.
This item can be shipped to United States, all countries in Europe, all countries in continental Asia, Canada, Brazil, Australia.