Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data. Simulate four kinds of temperature data. Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
Simulate standard ECG calibration, adult and pediatric ECG signal. ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested. Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.
Power supply: rechargeable lithium battery or linear adapter, which reduces interference. Optional operation modes: keys and touch screen. ECG Conventional: All leads have the same voltage with the II-lead as the reference Amplitude: 0.5,1.0,1.5 and 2.0mV ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180. 200,220,240,260,280,300,320,340 and 350 BPM. ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV. Arrhythmia Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia Ventricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole Premature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block. Four IBP Channels The default: 00/00mmHg Dynamic IBP(unit: mmHg) Channel 1. Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Ventricle: 25/00 Channel 2. Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Atrium(CVP): 15/10 Right Ventricle: 25/00 Pulmonary Artery: 25/10 Pulmonary Wedge: 10/2 Left Atrium: 14/4 Channel 3. Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Atrium(CVP): 15/10 Right Ventricle: 25/00 Pulmonary Artery: 25/10 Pulmonary Wedge: 10/2 Left Atrium: 14/4 Channel 4: Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge) Man Swan-Ganz: press ENTER key to change every time Static-Pressure Levels Channel 1: 0, 80, 160, 240, 320 and 400mmHg Channel 2: 0, 50, 100, 150, 200 and 250mmHg Channel 3: 0, 20, 40, 60, 80 and 100mmHg Channel 4: P4 tracks the static pressure levels of P3. Respiration Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN Impedance: 0.2, 0.5, 1.0 and 3.0 O Baseline impedance: 500, 1000, 1500, 2000O Apnea: 12 s, 22 s, 32 s. Standard accessories 9V/1A(CE) power adapter, an User manual, a packaging box, a plastic packaging. Optional accessories a power adapter(15V/1A)(UL), a power adapter(15V/1A), a temperature cable, an IBP cable, a CD disk(including a case conversion software). Dimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H) Net weight about 1.4kg. Food and Drug Administration and state and local regulatory agencies. If you have a defective item, you want to return or discount. Or replace item for you. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Training Manikins & Patient Simulators". The seller is "tialiy0" and is located in this country: US.This item can be shipped to United States, Canada, United Kingdom, Denmark, Romania, Slovakia, Bulgaria, Czech Republic, Finland, Hungary, Latvia, Lithuania, Malta, Estonia, Greece, Portugal, Cyprus, Slovenia, Sweden, Korea, South, Indonesia, South Africa, Thailand, Belgium, France, Hong Kong, Ireland, Netherlands, Poland, Spain, Italy, Germany, Austria, Bahamas, Israel, Mexico, New Zealand, Philippines, Singapore, Switzerland, Norway, Saudi Arabia, United Arab Emirates, Qatar, Kuwait, Bahrain, Croatia, Republic of, Malaysia, Brazil, Chile, Colombia, Costa Rica, Panama, Trinidad and Tobago, Guatemala, Honduras, Jamaica, Antigua and Barbuda, Aruba, Belize, Dominica, Grenada, Saint Kitts-Nevis, Saint Lucia, Montserrat, Turks and Caicos Islands, Barbados, Bangladesh, Bermuda, Brunei Darussalam, Bolivia, Ecuador, Egypt, French Guiana, Guernsey, Gibraltar, Guadeloupe, Iceland, Jersey, Jordan, Cambodia, Cayman Islands, Liechtenstein, Sri Lanka, Luxembourg, Monaco, Macau, Martinique, Maldives, Nicaragua, Oman, Peru, Pakistan, Paraguay, Reunion, Vietnam, Uruguay.