Wireless Connection Printer

MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex

MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex

MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex
MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter. Separated connection between simulator probe and host, operation and test are more convenient. 262K color and 320240 TFT, adjustable brightness level. Film key-press, makes the operation more comfortable. Power with chargeable lithium battery, can display the charge information of battery. Key volume, can open or close. Can test the reaction time of device. Can simulate the SpO2 and pulse rate under different amplitude.

Can test the performance of device under different interference source. Error: When SpO2 is 75%100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%. Measuring range:0.000%20.000%. Resolution:1% for 1.000%20.000%; 0.1% for 0.100%0.900%; 0.025% for 0.000%0.075%. 24 conditions presetting and 8 conditions as default after start.

The number of condition can be adjusted by Motion level setup. Voltage 3.7 rechargeable lithium battery × 1. Charge and discharge no less than 500 times. The sale of this item may be subject to regulation by the U. Food and Drug Administration and state and local regulatory agencies. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE &TUV of Europe. You can get the item in 10-25 days. You pay us what you see on the invoice, i.

Or replace item for you free of charge. Contec Medical Systems focusing on research, manufacture and distribution of medical instruments, was founded in 1992 as a high-tech company. At present there are more than 1200 employees in our company.

Our product line covers a wide range of 13 categories. Most of the domestic hospitals are our customers. Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners. We are looking forward to establishing a successful business relationship with you. Contec Medical Systems Contact name: Yoki.

This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Pulse Oximeters". The seller is "michewan-0" and is located in this country: US. This item can be shipped to United States.
  • Model: MS100 Spo2 Simulator
  • MPN: 69450401
  • Brand: CONTEC

MS100 SpO2 Simulator, Oxygen Saturation Simulation For Pulse Rate, USA Fedex