8Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and upper and lower limit of alarm can be set as necessary. 9Independent nonvolatile memory, storage for up to 2,000 groups of NIBP data and 78,000 groups of SpO2 data. 10Convenient and quick in reviewing measurement data, available for reviewing the NIBP trend graph of 24 hours and SpO2 trend graph of 22 hours. Using Oscillometry technology, also called Oscillography technology to measure the blood pressure.
2Measurement interval in auto mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min. 4Accuracy: max mean error: ±5 mmHg; max standard deviation: 8 mmHg. 5Overpressure protection: dual protection for both software and hardware. 6Others: reset, self-testing and accuracy testing of static pressure.Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the saturation of blood oxygen. 1Measurement range: 0 %100 %.
2Alarm range: 0 %100 %. 4Accuracy: 70 %100 %, ±2 %; below 70 % unspecified. Using Photoelectric Oxyhemoglobin Inspection Technology combined with Capacity Pulse Scanning & Recording Technology to measure the pulse rate. 1Measurement range: 25 bpm250 bpm. 2Alarm range: 25 bpm250 bpm.4Accuracy: ±2 bpm or ±2 %, whichever is greater. 4 Safety and Power supply. 1Power supply: rated voltage: 220 V, rated power: 50 Hz. 2Safety classification: Class I equipment, type BF defibrillation-proof applied part.
Dimension: 190 mm(L)×162 mm(W)×240 mm(H). Weight: about 1.6 kg.The sale of this item may be subject to regulation by the U. Food and Drug Administration and state and local regulatory agencies. 100% satisfaction is our goal!
If you have a defective item, you want to return or discount. I will try my best to give you a satisfied solution.
CONTEC Medical System-----Focusing on research, manufacture and distribution of medical equipment. CONTEC Medical System was founded in 1992 as a professional medical equipment producer. CONTEC was dedicating to research, manufacture and distribution of medical devices, now we have developed more than 20-category products contained Pulse Oximeter, Sphygmomanometer, ECG, EEG, Ultrasound Equipment, Fetal Doppler, Patient Monitor and Image Equipment, etc.Our products have passed CE, FDA and COS/VIOS certificate. At present, CONTEC produces and distributes more than 2000000 products per year, which were distributed to over 200 countries and regions. Looking forward to establishing a successful business relationship with you.
112 Qinhuang West Avenue, E&T Development zone, Qinhuangdao, China. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Patient Monitors". The seller is "chinamedicalshop" and is located in this country: CN. This item can be shipped worldwide.