Wireless Connection Printer

Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC

Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC
Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC

Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC

CMS9000 ICU Patient Monitor 7 Parameters Vital Signs Monitor ETCO2+Printer+. This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving. Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2RESP Respiration rate(RR) Respiration waveform 3SpO2 Pulse oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5TEMP T1, T2, TD It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

112.1'' TFT color LCD, multi-language interface:Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish(Europe), Spanish(Mexico), Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech, Bulgarian, Ukraine 2Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3All-round monitor for adult, pediatric and neonate. 4With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe. 5Waveform, parameter color and location can be set optionally. 6Operation mode: keys and buttons.

7Display up to 8-channel waveform on one screen. 8Display 7-lead ECG waveform on one screen, and with ECG step function.

9Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 11NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.

12Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 13Drug concentration calculation and titration table functions. 14Print trend table data with one-key. 15Connect to Central Monitoring System by 3G, WiFi or wired mode.

16AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 17Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary). ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-channel 3-lead, 1-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15300bpm Accuracy: ±1% or ±1bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV+2.0mV Accuracy: -0.8mv+0.8mv ±0.04mv or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes RESPIRATION Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0150rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 1040s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s NIBP Method: Oscillometry Mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in Continuous mode: 5 minutes Measurement and alarm range: 10 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg SpO2 Measurement and alarm range: 0 100% Resolution: 1% Measurement accuracy: 70%100%: ±2%; 0%69%: unspecified PR Measurement and alarm range: 25 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater TEMP Channel: dual-channel Measurement and alarm range: 0 50? EtCO2 Method: Sidestream or Mainstream Measurement range for CO2: 0150mmHg Resolution for CO2: 0 69 mmHg: 0.1 mmHg 70 150 mmHg: 0.25 mmHg Accuracy for CO2: 0 40 mmHg: ±2 mmHg 41 70 mmHg: ±5% 71 100 mmHg: ±8% 101 150 mmHg: ±10% AwRR range: 2150 rpm AwRR accuracy: ±1 rpm Apnea alarm: yes IBP Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -10300 mmHg Resolution: 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater Power supply:AC 100-240V, 50/60Hz Safety classification: Class I, type CF defibrillation-proof applied part.

Adult fingertip SpO2 probe (5-pin) Adult NIBP cuff NIBP extension tube ECG lead cable ECG electrode Temperature probe Power cord User Manual. Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H) Weight. Food and Drug Administration and state and local regulatory agencies. If you have a defective item, you want to return or discount. Or replace item for you.

These charges are buyers' responsibility. ECG / ECG holter EEG / EEG Holter B-ultrasound.

Patient Monitor Fetal doppler Fetal Monitor. Spo2 Monitor Stethoscope Medical Image...

We are look for partners in the world now! Do you want to become our agent in you conutry? Mary # hotmail dot com.

This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Patient Monitors". The seller is "chinamedicalshop" and is located in this country: CN. This item can be shipped to United States, all countries in Europe, Canada, Japan, Australia.

  • Model: CMS9000
  • Country/Region of Manufacture: China
  • Country of Manufacture: China
  • Features: Battery Operated, Printer
  • MPN: 69450401
  • Monitor Parameters: Blood Pressure, Blood Pressure - NIBP, Blood Pressure - ABPM, Blood Pressure - IBP, ECG, O2, O2 - SpO2, Respiratory Rate
  • Brand: CON-TEC
  • Intended Use/Discipline: Emergency Medicine, Internal Medicine, Medical Laboratory, Physical Laboratory, Physical Medicine & Rehabilitation


Patient Monitor ECG+NIBP+SPO2+PR+RESP+TEMP, Printer, EtCO2,2- IBP, ICU CCU CONTEC